GM0CSZ > IC706 22.04.05 22:58l 32 Lines 968 Bytes #999 (0) @ WW
BID : 591908GM0CSZ
Read: GUEST ON3DH
Subj: Re: S-Meter adjustment (CSZ)
Path: ON0AR<F6KMO<ON0BEL<VK7AX<GB7YKS<GB7PZT<GB7YFS<GB7CIP<GB7CRV<GB7FUR<
GB7IOM<GB7SAN<GB7INV<GB7NOS
Sent: 050421/2225Z @:GB7NOS.#76.GBR.EU #:31452 [Golspie] FBB7.00i $:591908GM0CS
From: GM0CSZ@GB7NOS.#76.GBR.EU
To : IC706@WW
G0FTD wrote:-
>
> The difference being 56db *in power* level (almost 60db), which is good
> enough.
>
> Is there anything wrong with that ?
===============================
Andy , You come to the conclusion that 32mV equals abt S9 + 56dB ; that is
correct.
However 60 dB is 4dB more than 56 dB and those additional 4dB can only be
achieved by increasing the voltage from 32 to 50 mV ;it is as simple as
that.
Voltage ratio being 50 /32 ,results in a power ratio of 2500 /1024 = 2.44
log 2.44 equals 0.39 Hence 0.39 Bell equals 3.9 dB or 4dB.
A few dB change results in quite a large change in voltage.
73 - Frank , GM0CSZ @ GB7NOS.#76.GBR.EU
Inver by Tain , IV20 1RX Scotland UK Loc: IO87AT
e-mail: gm0csz.kn6wh@ntlworld.com
Also in 2005 they say the future is bright ; 2 of its challenges remaining
to be RENEWABLE ENERGY and LINUX.
Message timed: 22:08 UTC on 21 Apr 2005